Development and Validation of a Rapid High-Performance Liquid Chromatography Method with UV Detection for the Determination of Vancomycin in Mouse Plasma

Krishna Muppidi, Andrew S. Pumerantz, Guru Betageri and Jeffrey Wang

rapid high-performance liquid chromatography (HPLC) method for the quantification of vancomycin in mouse plasma samples was developed and validated. Norvancomycin was used as the internal standard. Chromatographic separation was achieved on a Vydac C18 column (4.6×50 mm, 3 μm particle size) and the detection was made at 214 nm. A gradient elution was programmed with the mobile phases of 0.1% v/v trifluoroacetic acid (A) and 95:5 v/v acetonitrile: 0.1% TFA (B) and a flow rate of 1 ml/min. The total run time was 15 min. The calibration curve was linear over the range of 0.1-20 μg/ml, with a correlation coefficient (r) higher than 0.997 and the lower limit of quantitation (LLOQ) of 0.1 μg /ml. The intra-day accuracy values were between 90 and 112% and the inter-day ones ranged from 96 to 104%. Precision values ranged from 1.7 to 9.5% for intra-day and 6.3 to 9.4% for inter-day. Stability studies under normal laboratory conditions without significant loss of the drug. The assay was successfully applied to the pharmacokinetics and bio-distribution study of novel formulations of vancomycin in mice.

மறுப்பு: இந்த சுருக்கமானது செயற்கை நுண்ணறிவு கருவிகளைப் பயன்படுத்தி மொழிபெயர்க்கப்பட்டது மற்றும் இன்னும் மதிப்பாய்வு செய்யப்படவில்லை அல்லது சரிபார்க்கப்படவில்லை.